Rockwell Tools GUARDSHIELD SAFE 4 Instrukcja Użytkownika Strona 13

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 15
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 12
Type A
Protective Height
B
Mounting
C
Total Length
D
Mounting
440L-C4*L0320YD 320±0.5 516 552±1.5 426
440L-C4*L0480YD 480±0.5 676 712±1.5 586
440L-C4*L0640YD 640±0.5 836 872±1.5 746
440L-C4*L0800YD 800±0.5 996 1032±1.5 906
440L-C4*L0960YD 960±0.5 1156 1192±1.5 1066
440L-C4*L1120YD 1120±0.5 1316 1352±1.5 1226
440L-C4*L1280YD 1280±0.5 1476 1512±1.5 1386
440L-C4*L1440YD 1440±0.5 1636 1672±1.5 1546
440L-C4*L1600YD 1600±0.5 1796 1832±1.5 1706
J = 14 mm resolution, K = 30 mm resolution
Wiring Diagram for Connection of OSSDs Directly to Contactors (FSDs) with Restart Interlock
Wiring diagram is not intended to be used for installation purposes.
Auxiliaryoutputisnonsafety.Canbeconnectedtoalamp,motororstatustoaPLC.
K1, K2 Safety relay or safety contactor for OSSD 1 and OSSD 2 connection
S1 Switch for external system test (optional)
S2 Switch for reset of light curtain from start/restart interlock
Wiring Diagram for Connection of OSSDs Directly to a Safety Relay Module
Przeglądanie stron 12